This work was carried out by Ansaldo Nucleare in co-operation with the Nuclear Data Group of the ENEA/FIS-NUC Section and represents an example of a heavy and complex industrial application simulated with the TORT 3D deterministic transport code, supported by the BOT3P pre-post-processor system far the automatic spatial mesh generation and graphical verification. It is underlined that the development and validation of BOT3P was originally performed in ENEA-Bologna.
WESTINGHOUSE AP1000 Internals Heating Rate Distribution Calculation Using a 3D Deterministic Transport Method
Pescarini, M.;Orsi, R.;
2005-05-16
Abstract
This work was carried out by Ansaldo Nucleare in co-operation with the Nuclear Data Group of the ENEA/FIS-NUC Section and represents an example of a heavy and complex industrial application simulated with the TORT 3D deterministic transport code, supported by the BOT3P pre-post-processor system far the automatic spatial mesh generation and graphical verification. It is underlined that the development and validation of BOT3P was originally performed in ENEA-Bologna.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.