ASTEC and MELCOR are the two codes used to perform a code-to-code and a codes-to-experimental data comparison with the help of data and experimental results made available during the CSNI/ISP n. 46, related to FPT1 of the PHEBUS-FP experimental facility.

ASTEC AND MELCOR RESULTS COMPARED WITH AVAILABLE DATA FROM CSNI/ISP n. 46 (PHEBUS FPT1)

De Rosa, F.
2005-06-27

Abstract

ASTEC and MELCOR are the two codes used to perform a code-to-code and a codes-to-experimental data comparison with the help of data and experimental results made available during the CSNI/ISP n. 46, related to FPT1 of the PHEBUS-FP experimental facility.
27-giu-2005
Rapporto tecnico;Sicurezza nucleare;Analisi incidentale;Reattori nucleari ad acqua