The creation of a network infrastructure is complex and involves multiple technical and technological aspects. The first aspect concerns the physical infrastructure, in particular the distribution of the passive telematic network and the cabling of the buildings, through a well-structured project with the aim of creating a network that has homogeneous physical connectivity, performance in terms of speed adapted to the needs current and future, therefore to be scalable, with possible technological evolutions and with the possibility of future expansions, and finally to support the standard communication protocols; The second aspect concerns the distribution of the active telematic network or the distribution of telematic devices such as routers, switches, firewalls and the correct management and maintenance of telematic cabinets. The third aspect concerns the implementation of the network from a logical point of view. The logical scheme of a network is an abstraction from the physical and structural level and allows its implementation according to an idea of security, reliability, resilience and accessibility, through the use of security policies, network segmentation, accessibility rules etc. A further aspect concerns the physical infrastructure of the Data Center, the correct implementation of the same, the installation and implementation of Servers and Storage for the distribution of services, air conditioning of the environments, electrical continuity, fault tolerance and more.
La realizzazione di un’infrastruttura di rete è complessa e riguarda molteplici aspetti tecnici e tecnologici. Il primo aspetto riguarda l’infrastruttura fisica, in particolare la distribuzione della rete telematica passiva e la cablatura degli edifici, mediante un progetto ben strutturato con l’obiettivo di realizzare una rete che abbia connettività fisica omogenea, prestazioni in termini di velocità adeguate alle esigenze attuali e future, essere dunque scalabile, con possibili evoluzioni tecnologiche e con possibilità di espansioni future, infine supportare i protocolli standard di comunicazione; Il secondo aspetto riguarda la distribuzione della rete telematica attiva ovvero la distribuzione degli apparati telematici quali router, switch, firewall e la corretta gestione e mantenimento degli armadi telematici. Il terzo aspetto riguarda l’implementazione della rete dal punto di vista logico. Lo schema logico di una rete è una astrazione dal livello fisico e strutturale e ne permette l’implementazione secondo una idea di sicurezza, affidabilità, resilienza e accessibilità, mediante l’utilizzo di politiche di sicurezza, segmentazione della rete, regole di accessibilità ecc. Un ulteriore aspetto riguarda l’infrastruttura fisica del Data Center, la corretta realizzazione dello stesso, l’installazione e implementazione di Server e Storage per la distribuzione dei servizi, la climatizzazione degli ambienti, la continuità elettrica, la tolleranza ai guasti e altro ancora.
Realizzazione dell'infrastruttura di rete del Centro ENEA di Brindisi
Cannataro, G.;Caretto, G.
2020-01-01
Abstract
The creation of a network infrastructure is complex and involves multiple technical and technological aspects. The first aspect concerns the physical infrastructure, in particular the distribution of the passive telematic network and the cabling of the buildings, through a well-structured project with the aim of creating a network that has homogeneous physical connectivity, performance in terms of speed adapted to the needs current and future, therefore to be scalable, with possible technological evolutions and with the possibility of future expansions, and finally to support the standard communication protocols; The second aspect concerns the distribution of the active telematic network or the distribution of telematic devices such as routers, switches, firewalls and the correct management and maintenance of telematic cabinets. The third aspect concerns the implementation of the network from a logical point of view. The logical scheme of a network is an abstraction from the physical and structural level and allows its implementation according to an idea of security, reliability, resilience and accessibility, through the use of security policies, network segmentation, accessibility rules etc. A further aspect concerns the physical infrastructure of the Data Center, the correct implementation of the same, the installation and implementation of Servers and Storage for the distribution of services, air conditioning of the environments, electrical continuity, fault tolerance and more.File | Dimensione | Formato | |
---|---|---|---|
RT-2020-06-ENEA.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
4.8 MB
Formato
Adobe PDF
|
4.8 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.