The divertor is one of the most challenging components of "DEMO" the next step ITER machine, so many tasks regarding modeling and experiments have been made in the past years to assess manufacturing processes, materials and thus the life-time of the components. In this context the finite element analysis (FEA) allows designers to explore multiple design options, to reduce physical prototypes and to optimize design performance. The comparison between the hydraulic thermal-mechanical analysis performed by ANSYS WORKBENCH 14.5 and the test results [1] on small-scale mock-ups manufactured with the Hot Radial Pressing (HRP) [2] technology is presented in this paper. During the thermal fatigue testing in the Efremov TSEFEY facility to assess the heat flux load-carrying capability of the mock-ups, only the surface temperature was measured, so the FEA was important because it allowed to know any other information (temperature inside the materials, local water temperature, local stress, etc.). FEA was performed coupling the thermal-hydraulic analysis, that calculated the temperature distributions on the components and the heat transfer coefficient (HTC) between water and heat sink tube, with the mechanical analysis. The comparison between analysis and testing results was based on the temperature maps of the loaded surface and on number of the cycles supported during the testing and those predicted by the mechanical analysis using the experimental fatigue curves for CuCrZr-IG, that is the structural material in the component. Also the behavior for Cu-OFHC interlayer material based on the experimental fatigue curves was considered and the ultimate tensile strength for W, because their failure affects the heat removal capability of the component. The good correlation found between FEA results and testing campaign validated again the use of FEA itself for future design improved concepts. © 2014 EURATOM-ENEA Association.

Comparison between FEM and high heat flux thermal fatigue testing results of ITER divertor plasma facing mock-ups

Crescenzi, F.;Moriani, A.;Visca, E.;Roccella, S.
2014-01-01

Abstract

The divertor is one of the most challenging components of "DEMO" the next step ITER machine, so many tasks regarding modeling and experiments have been made in the past years to assess manufacturing processes, materials and thus the life-time of the components. In this context the finite element analysis (FEA) allows designers to explore multiple design options, to reduce physical prototypes and to optimize design performance. The comparison between the hydraulic thermal-mechanical analysis performed by ANSYS WORKBENCH 14.5 and the test results [1] on small-scale mock-ups manufactured with the Hot Radial Pressing (HRP) [2] technology is presented in this paper. During the thermal fatigue testing in the Efremov TSEFEY facility to assess the heat flux load-carrying capability of the mock-ups, only the surface temperature was measured, so the FEA was important because it allowed to know any other information (temperature inside the materials, local water temperature, local stress, etc.). FEA was performed coupling the thermal-hydraulic analysis, that calculated the temperature distributions on the components and the heat transfer coefficient (HTC) between water and heat sink tube, with the mechanical analysis. The comparison between analysis and testing results was based on the temperature maps of the loaded surface and on number of the cycles supported during the testing and those predicted by the mechanical analysis using the experimental fatigue curves for CuCrZr-IG, that is the structural material in the component. Also the behavior for Cu-OFHC interlayer material based on the experimental fatigue curves was considered and the ultimate tensile strength for W, because their failure affects the heat removal capability of the component. The good correlation found between FEA results and testing campaign validated again the use of FEA itself for future design improved concepts. © 2014 EURATOM-ENEA Association.
2014
Computational fluid dynamic (CFD);ANSYS code;PFC;High heat flux testing (HHF);Non-destructive testing (NDT)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/5871
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact