Accurate sensors validation is a fundamental requirement in air quality monitoring. Validated multisensor could in fact be used as tools to provide indicative measurements to compliment data coming from regulatory monitoring stations. The sparseness of the conventional analyzers, do not allow to have a dense background and prevent the possibility to achieve a high resolution picture of pollutants concentrations in cities and validated Air Quality multisensor could provide a solution to the lack of resolution. Currently, the most accredited validation procedure involves in field data recording in co-location with reference instrumentation. In this work, we show the results of a validation experiment implemented co-locating the ENEA MONICA platform together with an ARPAC (Campania Regional Agency for Environmental Protection) conventional analyzer, during 8 months. The obtained results encourage the possible use of MONICA multisensor platform as a backup tool for reference analyzers.

Mid Term Field Validation of the MONICA Air Quality Multisensor

Esposito E.;De Vito S.;Formisano F.;Massera E.;Fattoruso G.;Di Francia G.
2020-01-01

Abstract

Accurate sensors validation is a fundamental requirement in air quality monitoring. Validated multisensor could in fact be used as tools to provide indicative measurements to compliment data coming from regulatory monitoring stations. The sparseness of the conventional analyzers, do not allow to have a dense background and prevent the possibility to achieve a high resolution picture of pollutants concentrations in cities and validated Air Quality multisensor could provide a solution to the lack of resolution. Currently, the most accredited validation procedure involves in field data recording in co-location with reference instrumentation. In this work, we show the results of a validation experiment implemented co-locating the ENEA MONICA platform together with an ARPAC (Campania Regional Agency for Environmental Protection) conventional analyzer, during 8 months. The obtained results encourage the possible use of MONICA multisensor platform as a backup tool for reference analyzers.
2020
978-3-030-37557-7
978-3-030-37558-4
Air quality multisensor systems
Field calibration
Reference backup data
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/59225