Transparent adaptive façade components are designed to improve either visual comfort aspects or the energy performance of a building. Focusing only on one domain implies drawbacks that negatively influence the performance of the component itself. This paper hence presents a novel multiobjective methodology aimed at determining the most viable trade-off between energy performance and comfort issues for active components. This multi-objective optimization strategy was applied to a thermochromic glazing (TCG), i.e. a passive transparent façade component whose thermo-optical properties vary in response to its thermo chromic layer temperature. As one of the key elements of the methodology, the influence of TCG hysteresis on visual comfort and energy performance was taken into account. The hysteresis of the TCG in an enclosed office was determined for 3 different climates and for five hysteresis widths. The results obtained show that, for all the cases analyzed, the hysteresis influence on the overall energy performance is negligible, whilst it can significantly affect visual comfort, both in terms of workplane horizontal illuminance and perceived glare. İ 2018 IEEE.

A Novel Methodology to Optimize Visual Comfort and Energy Performance for Transparent Adaptive Façades

Zinzi, M.
2018-01-01

Abstract

Transparent adaptive façade components are designed to improve either visual comfort aspects or the energy performance of a building. Focusing only on one domain implies drawbacks that negatively influence the performance of the component itself. This paper hence presents a novel multiobjective methodology aimed at determining the most viable trade-off between energy performance and comfort issues for active components. This multi-objective optimization strategy was applied to a thermochromic glazing (TCG), i.e. a passive transparent façade component whose thermo-optical properties vary in response to its thermo chromic layer temperature. As one of the key elements of the methodology, the influence of TCG hysteresis on visual comfort and energy performance was taken into account. The hysteresis of the TCG in an enclosed office was determined for 3 different climates and for five hysteresis widths. The results obtained show that, for all the cases analyzed, the hysteresis influence on the overall energy performance is negligible, whilst it can significantly affect visual comfort, both in terms of workplane horizontal illuminance and perceived glare. İ 2018 IEEE.
2018
9781538651858
visual comfort;glare;adaptive façades;energy performance;multi-objective optimization strategy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/6008
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact