In this report the IFMIF lithium Target safety analysis is presented. The safety review includes the hazard analysis adopting the FMEA (Failure Mode and Effect Analysis) methodology, and the systems analysis aimed at evaluating the reliability of the system through the fault tree technique. Thermal transient analysis of lithium Target loop is described in the latter section of the document.
IFMIF Lithium Target Safety
Burgazzi, L.
2003-02-25
Abstract
In this report the IFMIF lithium Target safety analysis is presented. The safety review includes the hazard analysis adopting the FMEA (Failure Mode and Effect Analysis) methodology, and the systems analysis aimed at evaluating the reliability of the system through the fault tree technique. Thermal transient analysis of lithium Target loop is described in the latter section of the document.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.