Neutron streaming fluxes in the vacuum tube of the LBE-Cooled PDS-XADS have been calculated in a 63 energy group structure. Gamma sources and doses at 3 cooling times: 1 day, 7 days and 1 year after 930 days of operation have been calculated in the zone above the reactor roof. Neutron streaming in the vacuum tube is an important contributor to the activation doses but not the only one.
PDS-XADS Neutron Streaming in the Vacuum Tube and Doses from Neutron Activation in the Zone above the Roof
Burn, K.
2004-07-29
Abstract
Neutron streaming fluxes in the vacuum tube of the LBE-Cooled PDS-XADS have been calculated in a 63 energy group structure. Gamma sources and doses at 3 cooling times: 1 day, 7 days and 1 year after 930 days of operation have been calculated in the zone above the reactor roof. Neutron streaming in the vacuum tube is an important contributor to the activation doses but not the only one.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.