In the present paper an integrated approach of a wide range of non-destructive tests (NDTs) was applied to study an archeological ruined building located in Rome, the so-called Temple of Minerva Medica. Applied NDTs focused on the monument properties and environmental conditions affecting its structural behavior (geometry, thermal and mechanical properties, microclimatic monitoring, ambient vibration response). Two surveys were performed in August and December 2016 combining 3D laser scanning, thermal infrared, air temperature and relative humidity acquisitions. In addition, high resolution digital images were acquired and processed by stereo-photogrammetry Structure from Motion (SfM) methodology, carried out for detailed reconstruction of the crack pattern of the monument. In order to obtain information on the integrity and consistency of the masonry, a sonic testing of each pillar was also performed. The integration of the above NDTs provided quite complete and comprehensive understanding of the structural behavior and state of the building, reducing the amount of invasive measurements further needed. © 2018 IMEKO.

Integrated approach to structural diagnosis by nondestructive techniques: The case of the Temple of Minerva Medica

De Canio, G.;Romano, R.;Mongelli, M.;Fioriti, V.;Tatì, A.;Roselli, I.
2018-01-01

Abstract

In the present paper an integrated approach of a wide range of non-destructive tests (NDTs) was applied to study an archeological ruined building located in Rome, the so-called Temple of Minerva Medica. Applied NDTs focused on the monument properties and environmental conditions affecting its structural behavior (geometry, thermal and mechanical properties, microclimatic monitoring, ambient vibration response). Two surveys were performed in August and December 2016 combining 3D laser scanning, thermal infrared, air temperature and relative humidity acquisitions. In addition, high resolution digital images were acquired and processed by stereo-photogrammetry Structure from Motion (SfM) methodology, carried out for detailed reconstruction of the crack pattern of the monument. In order to obtain information on the integrity and consistency of the masonry, a sonic testing of each pillar was also performed. The integration of the above NDTs provided quite complete and comprehensive understanding of the structural behavior and state of the building, reducing the amount of invasive measurements further needed. © 2018 IMEKO.
2018
Archaeological building;Integrated approach;Non-destructive tests
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/1999
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact