Current state of the art solutions based on the Triple to Double Coincidence Ratio method are generally large size, heavy-weight and not transportable systems. This is due, on one side, to large detectors and scintillation chambers and, on the other, to bulky analog electronics for data acquisition. CAEN developed a new, full digital approach to TDCR technique based on a portable, stand-alone, high-speed multichannel digitizer, on-board Digital Pulse Processing and dedicated DAQ software that emulates the well-known MAC3 analog board. © 2013 Elsevier Ltd.

A full digital approach to the TDCR method

Capogni, M.
2014-01-01

Abstract

Current state of the art solutions based on the Triple to Double Coincidence Ratio method are generally large size, heavy-weight and not transportable systems. This is due, on one side, to large detectors and scintillation chambers and, on the other, to bulky analog electronics for data acquisition. CAEN developed a new, full digital approach to TDCR technique based on a portable, stand-alone, high-speed multichannel digitizer, on-board Digital Pulse Processing and dedicated DAQ software that emulates the well-known MAC3 analog board. © 2013 Elsevier Ltd.
2014
TDCR method;Digital pulse processing;Liquid scintillation;Radionuclide metrology