The neutron efficiency of a Gas Electron Multiplier (GEM)-based detector designed for fast neutron measurements in fusion devices was determined through the combined use of Monte Carlo (MCNPX) calculations and analysis of deuterium-deuterium and deuterium-tritium neutron irradiation experiments. The detector, characterized by a triple GEM structure flushed with a Ar/CO 2/CF4 - 45/15/40 gas mixture, features a digital read-out system and has two sub-units for the detection of 2.5+14 MeV neutrons and 14 MeV neutrons (UDD and UDT, respectively). The pulse height spectra (PHS) determined from the curves of experimental efficiency as a function of the detector's high voltage (HV) and the MCNPX-simulated PHS were compared using a fitting routine that finds the best match between the experimental and simulated PHS by assuming a parametric model for the relation between HV (that determines the detector's gain) and the energy deposited in the gas. This led to express the experimental neutron efficiency as a function of the discrimination level set on the deposited energy (energy threshold). The detector sensitivity to γ-rays was also analyzed and the operational range in which the γ-ray contribution to the signal is not negligible was determined. It is found that this detector can reach a maximum neutron efficiency of ∼1×10-3 counts/n at 2.5 MeV (UDD sub-unit) and of ∼4×10-3 counts/n at 14 MeV (UDT and UDD sub-units). © 2014 The Authors.

Characterization of a GEM-based fast neutron detector

Villari, R.;Esposito, B.;Marocco, D.
2014-01-01

Abstract

The neutron efficiency of a Gas Electron Multiplier (GEM)-based detector designed for fast neutron measurements in fusion devices was determined through the combined use of Monte Carlo (MCNPX) calculations and analysis of deuterium-deuterium and deuterium-tritium neutron irradiation experiments. The detector, characterized by a triple GEM structure flushed with a Ar/CO 2/CF4 - 45/15/40 gas mixture, features a digital read-out system and has two sub-units for the detection of 2.5+14 MeV neutrons and 14 MeV neutrons (UDD and UDT, respectively). The pulse height spectra (PHS) determined from the curves of experimental efficiency as a function of the detector's high voltage (HV) and the MCNPX-simulated PHS were compared using a fitting routine that finds the best match between the experimental and simulated PHS by assuming a parametric model for the relation between HV (that determines the detector's gain) and the energy deposited in the gas. This led to express the experimental neutron efficiency as a function of the discrimination level set on the deposited energy (energy threshold). The detector sensitivity to γ-rays was also analyzed and the operational range in which the γ-ray contribution to the signal is not negligible was determined. It is found that this detector can reach a maximum neutron efficiency of ∼1×10-3 counts/n at 2.5 MeV (UDD sub-unit) and of ∼4×10-3 counts/n at 14 MeV (UDT and UDD sub-units). © 2014 The Authors.
2014
GEM;Neutron detector;Fusion
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/2861
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact