The aim of this paper was to propose a novel approach to the ultrasound (US) characterization of human bones through an improved measurement of the apparent integrated backscatter (AIB). Four intact human femoral heads were studied ex vivo in their physiologic morphological configuration, including cartilaginous, cortical and trabecular regions. Each sample underwent an US acquisition performed with a clinically-available echographic device and a micro-computed tomography (micro-CT) scan, whose spatial resolution was preliminarily optimized for this specific purpose. A dedicated US signal compensation was employed in the AIB computation, to take into account the variability of sample-probe distance and cortical bone thickness. Obtained results showed an appreciable global correlation between AIB and the trabecular bone volume fraction as quantified by the micro-CT parameter BV/TV (|r| = 0.69). The proposed approach has interesting perspectives for a clinical translation as an innovative method for in vivo US measurement of proximal femur bone density. © 2016 Elsevier Ltd. All rights reserved.

A new approach for measuring the trabecular bone density through the echosound backscattering: An ex vivo validation on human femoral heads

De Pascalis, F.
2016-01-01

Abstract

The aim of this paper was to propose a novel approach to the ultrasound (US) characterization of human bones through an improved measurement of the apparent integrated backscatter (AIB). Four intact human femoral heads were studied ex vivo in their physiologic morphological configuration, including cartilaginous, cortical and trabecular regions. Each sample underwent an US acquisition performed with a clinically-available echographic device and a micro-computed tomography (micro-CT) scan, whose spatial resolution was preliminarily optimized for this specific purpose. A dedicated US signal compensation was employed in the AIB computation, to take into account the variability of sample-probe distance and cortical bone thickness. Obtained results showed an appreciable global correlation between AIB and the trabecular bone volume fraction as quantified by the micro-CT parameter BV/TV (|r| = 0.69). The proposed approach has interesting perspectives for a clinical translation as an innovative method for in vivo US measurement of proximal femur bone density. © 2016 Elsevier Ltd. All rights reserved.
2016
Micro-CT;Apparent integrated backscatter;Bone volume fraction;Ultrasound signal processing;Femoral head
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/3096
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact