This paper provides a multi-objective optimization of a hybrid organic Rankine plant for solar and low-grade energy sources. In this plant, water, with a mass flow rate of 1 kg/s at a temperature of 90 °C, preheats the working fluid. The objective of this work is to search for solutions with the highest first and second law efficiencies of the plant and the lowest LEC (levelized energy cost). The design parameters are i) the working fluid, ii) the evaporating and condensing pressure, iii) the maximum temperature of the collector thermal fluid and iv) a parameter representative of the temperature profiles in the heat exchangers. A NSGAII (non-dominated sorting genetic algorithm) has been used. The Pareto front solutions provide Cyclopropane, R143a and R32 as working fluids. The lowest LEC (0.114 $/kWh) and the highest first law efficiency (9.65%) are achieved by using Cyclopropane, with a power output greater than 100 kW. The highest second law efficiency (44%) is obtained by employing R143a, with a low contribution of the solar source and a power output greater than 10 kW. Finally, R32 solutions have comparable performance with respect to R143a solutions. © 2015 Elsevier Ltd.

A genetic optimization of a hybrid organic Rankine plant for solar and low-grade energy sources

Fanelli, E.;Braccio, G.
2015-01-01

Abstract

This paper provides a multi-objective optimization of a hybrid organic Rankine plant for solar and low-grade energy sources. In this plant, water, with a mass flow rate of 1 kg/s at a temperature of 90 °C, preheats the working fluid. The objective of this work is to search for solutions with the highest first and second law efficiencies of the plant and the lowest LEC (levelized energy cost). The design parameters are i) the working fluid, ii) the evaporating and condensing pressure, iii) the maximum temperature of the collector thermal fluid and iv) a parameter representative of the temperature profiles in the heat exchangers. A NSGAII (non-dominated sorting genetic algorithm) has been used. The Pareto front solutions provide Cyclopropane, R143a and R32 as working fluids. The lowest LEC (0.114 $/kWh) and the highest first law efficiency (9.65%) are achieved by using Cyclopropane, with a power output greater than 100 kW. The highest second law efficiency (44%) is obtained by employing R143a, with a low contribution of the solar source and a power output greater than 10 kW. Finally, R32 solutions have comparable performance with respect to R143a solutions. © 2015 Elsevier Ltd.
2015
Solar energy;Thermo-economic analysis;Organic Rankine cycle;Multi-objective genetic algorithm;Low-grade energy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/623
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact