Indoor Environmental Quality (IEQ) is a crucial issue in school buildings, because of the conditions that pupils and students are exposed to. From this assumption, potentialities of retrofit actions with Nearly Zero-Energy Building (NZEB) targets were analyzed in existing school buildings, focusing on the impact of such measures of IEQ. Numerical analyses in a transient regime for a typical school building were carried out to assess the impacts on the thermal comfort and Indoor Air Quality (IAQ). The study took into account several building configurations and three reference cities. The results showed severe overheating risks in retrofitted schools: the operative temperature increased by several degrees with respect to the existing configuration, leading to thermal discomfort for a relevant part of the observation period. Passive techniques, namely external solar protection devices and night ventilative cooling, were applied to assess their mitigation potential. Results showed that the combination of the two solutions restored the pre-retrofit performance. CO2 levels were found to be too high for naturally ventilated buildings, regardless of the building configuration; acceptable levels might be reached only with long opening times of windows, which are unrealistic for real building operation.

On the built-environment quality in nearly zero-energy renovated schools: Assessment and impact of passive strategies

Zinzi M.;Pagliaro F.;Agnoli S.;Iatauro D.
2021-01-01

Abstract

Indoor Environmental Quality (IEQ) is a crucial issue in school buildings, because of the conditions that pupils and students are exposed to. From this assumption, potentialities of retrofit actions with Nearly Zero-Energy Building (NZEB) targets were analyzed in existing school buildings, focusing on the impact of such measures of IEQ. Numerical analyses in a transient regime for a typical school building were carried out to assess the impacts on the thermal comfort and Indoor Air Quality (IAQ). The study took into account several building configurations and three reference cities. The results showed severe overheating risks in retrofitted schools: the operative temperature increased by several degrees with respect to the existing configuration, leading to thermal discomfort for a relevant part of the observation period. Passive techniques, namely external solar protection devices and night ventilative cooling, were applied to assess their mitigation potential. Results showed that the combination of the two solutions restored the pre-retrofit performance. CO2 levels were found to be too high for naturally ventilated buildings, regardless of the building configuration; acceptable levels might be reached only with long opening times of windows, which are unrealistic for real building operation.
2021
Building energy performance
Indoor Air Quality
Indoor environmental quality
Nearly Zero-Energy Buildings
School buildings
Thermal comfort
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/64788
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
social impact