Due to their attractive properties, such as high energy and power density, Lithium-ion batteries are currently the most suitable energy storage system for powering portable electronic equipment, electric vehicles, etc. However, they are still affected by safety and stability problems that need to be solved to allow a wider range of applications, especially for critical areas such as power networks and aeronautics. In this paper, the issue of overdischarge abuse has been addressed on Lithium-ion cells with different anode materials: a graphite-based anode and a Lithium Titanate Oxide (LTO)-based anode model. Tests were carried out at different depths of discharge (DOD%) in order to determine the effect of DOD% on cell performance and the critical conditions that often make the cell fail irreversibly. Tests on graphite anode cells have shown that at DOD% higher than 110% the cell is damaged irreversibly; while at DOD% lower than 110% electrolyte deposits form on the anodic surface and structural damage affects the cathode during cycling after the overdischarge. Furthermore, at any DOD%, copper deposits are found on the anode. In contrast with the graphite anode, it was always possible to recharge the LTO-based anode cells and restore their operation, though in the case of DOD% of 140% a drastic reduction in the recovered capacity was observed. In no case was there any venting of the cell, or any explosive event.

Experimental Investigation of Overdischarge Effects on Commercial Li-Ion Cells

Menale C.;Sglavo V.;Della Seta L.;
2022-01-01

Abstract

Due to their attractive properties, such as high energy and power density, Lithium-ion batteries are currently the most suitable energy storage system for powering portable electronic equipment, electric vehicles, etc. However, they are still affected by safety and stability problems that need to be solved to allow a wider range of applications, especially for critical areas such as power networks and aeronautics. In this paper, the issue of overdischarge abuse has been addressed on Lithium-ion cells with different anode materials: a graphite-based anode and a Lithium Titanate Oxide (LTO)-based anode model. Tests were carried out at different depths of discharge (DOD%) in order to determine the effect of DOD% on cell performance and the critical conditions that often make the cell fail irreversibly. Tests on graphite anode cells have shown that at DOD% higher than 110% the cell is damaged irreversibly; while at DOD% lower than 110% electrolyte deposits form on the anodic surface and structural damage affects the cathode during cycling after the overdischarge. Furthermore, at any DOD%, copper deposits are found on the anode. In contrast with the graphite anode, it was always possible to recharge the LTO-based anode cells and restore their operation, though in the case of DOD% of 140% a drastic reduction in the recovered capacity was observed. In no case was there any venting of the cell, or any explosive event.
2022
abuse test
battery safety
energy storage
lithium-ion batteries
overdischarge
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/66787
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
social impact