The Crilin calorimeter represents a novel approach in the development of electromagnetic calorimeters for future colliders, especially for a Muon Collider. This paper details the design and performance of the innovative semi-homogeneous Crilin calorimeter, highlighting its capabilities in mitigating beam-induced backgrounds (BIB) while maintaining excellent time resolution (less than 50 ps), longitudinal segmentation, and fine granularity. These performances are achieved throughout a series of stackable and interchangeable lead fluoride (PbF2) crystal matrices readout by surface-mount UV-extended Silicon Photo-multipliers. Simulated and experimental results demonstrate the Crilin design's potential to work as an efficient and cost-effective alternative to traditional electromagnetic calorimeters. Crilin radiation tolerance is discussed, as measured in several irradiation campaigns, as well as timing performances during a beam test at CERN-H2 with 120 GeV electrons for the latest prototype, Proto-1. Additionally, a description of the results from a recent beam test conducted at the LNF Beam Test Facility with 450 MeV electrons is provided, aiming to measure light yield losses due to irradiation.

Developing an alternative calorimeter solution for the future Muon Collider: The Crilin design

Cemmi A.;Colao F.;Di Sarcina I.;Verna A.;
2024-01-01

Abstract

The Crilin calorimeter represents a novel approach in the development of electromagnetic calorimeters for future colliders, especially for a Muon Collider. This paper details the design and performance of the innovative semi-homogeneous Crilin calorimeter, highlighting its capabilities in mitigating beam-induced backgrounds (BIB) while maintaining excellent time resolution (less than 50 ps), longitudinal segmentation, and fine granularity. These performances are achieved throughout a series of stackable and interchangeable lead fluoride (PbF2) crystal matrices readout by surface-mount UV-extended Silicon Photo-multipliers. Simulated and experimental results demonstrate the Crilin design's potential to work as an efficient and cost-effective alternative to traditional electromagnetic calorimeters. Crilin radiation tolerance is discussed, as measured in several irradiation campaigns, as well as timing performances during a beam test at CERN-H2 with 120 GeV electrons for the latest prototype, Proto-1. Additionally, a description of the results from a recent beam test conducted at the LNF Beam Test Facility with 450 MeV electrons is provided, aiming to measure light yield losses due to irradiation.
2024
Crystals
Electromagnetic calorimeter
Muon Collider
SiPMs
File in questo prodotto:
File Dimensione Formato  
Developing an alternative calorimeter solution for the future Muon Collider_ The Crilin design.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.98 MB
Formato Adobe PDF
1.98 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/80147
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact