Lithium ion batteries are currently the main technology for storing energy in electric vehicles thanks to their high power density and energy density. Among the many challenges, safety related aspects must be faced. The thermal runaway caused by overcharge is one of the main weak points to be addressed to ensure a proper level of safety, necessary for the diffusion of this technology.Nowadays, many cells have integrated protection devices that reduce the risk of thermal runaway triggered by overcharging. In this study, the efficiency of devices used to prevent the thermal runaway, caused by overcharging cylindrical 18650 lithium-ion cells with graphite anode, is evaluated. Experimental tests were carried out at different ambient temperatures and overcharge currents.In all the cases the intervention of the Current Interrupt Device avoids the thermal runaway occurrence, preventing the intervention of the others protection devices such as the Positive Temperature Coefficient device and the safety vent.

Analysis of the Effects of Overcharging Lithium Ion Cells with Graphite Anode: Efficiency of Protection Devices Integrated into the Cells

Menale C.;Sglavo V.;Vellucci F.;Scotini A.
2024-01-01

Abstract

Lithium ion batteries are currently the main technology for storing energy in electric vehicles thanks to their high power density and energy density. Among the many challenges, safety related aspects must be faced. The thermal runaway caused by overcharge is one of the main weak points to be addressed to ensure a proper level of safety, necessary for the diffusion of this technology.Nowadays, many cells have integrated protection devices that reduce the risk of thermal runaway triggered by overcharging. In this study, the efficiency of devices used to prevent the thermal runaway, caused by overcharging cylindrical 18650 lithium-ion cells with graphite anode, is evaluated. Experimental tests were carried out at different ambient temperatures and overcharge currents.In all the cases the intervention of the Current Interrupt Device avoids the thermal runaway occurrence, preventing the intervention of the others protection devices such as the Positive Temperature Coefficient device and the safety vent.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12079/84690
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact