Ceramic tile production is an industrial process where energy efficiency management is crucial, given the high amount of energy (electrical and thermal) required by the production cycle. This study presents the preliminary results of a research project aimed at defining the benefits of using combined heat and power (CHP) systems in the ceramic sector. Data collected from ten CHP installations allowed us to outline the average characteristics of prime movers, and to quantify the contribution of CHP thermal energy supporting the dryer process. The electric size of the installed CHP units resulted in being between 3.4 MW and 4.9 MW, with an average value of 4 MW. Data revealed that when the goal is to maximize the generation of electricity for self-consumption, internal combustion engines are the preferred choice due to higher conversion efficiency. In contrast, gas turbines allowed us to minimize the consumption of natural gas input to the spray dryer. Indeed, the fraction of the dryer thermal demand (between 600–950 kcal/kgH2O), covered by CHP discharged heat, is strictly dependent on the type of prime mover installed: lower values, in the range of 30–45%, are characteristic of combustion engines, whereas the use of gas turbines can contribute up to 77% of the process’s total consumption.
Cogeneration supporting the energy transition in the italian ceramic tile industry
Salvio M.;Toro C.;Martini F.;
2021-01-01
Abstract
Ceramic tile production is an industrial process where energy efficiency management is crucial, given the high amount of energy (electrical and thermal) required by the production cycle. This study presents the preliminary results of a research project aimed at defining the benefits of using combined heat and power (CHP) systems in the ceramic sector. Data collected from ten CHP installations allowed us to outline the average characteristics of prime movers, and to quantify the contribution of CHP thermal energy supporting the dryer process. The electric size of the installed CHP units resulted in being between 3.4 MW and 4.9 MW, with an average value of 4 MW. Data revealed that when the goal is to maximize the generation of electricity for self-consumption, internal combustion engines are the preferred choice due to higher conversion efficiency. In contrast, gas turbines allowed us to minimize the consumption of natural gas input to the spray dryer. Indeed, the fraction of the dryer thermal demand (between 600–950 kcal/kgH2O), covered by CHP discharged heat, is strictly dependent on the type of prime mover installed: lower values, in the range of 30–45%, are characteristic of combustion engines, whereas the use of gas turbines can contribute up to 77% of the process’s total consumption.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.